Photo Gallery

1972 GE 2500L (147 W / 6.6 A)

The lamp shown here has become quite a rarity nowadays as municipalities across North America have retired their obsolete incandescent streetlight luminaires with LED counterparts (or are in the process of doing so). The present 2500L is a special incandescent lamp which was designed specifically for an operation on 6.6 A series circuits that once were popular in the USA in street-lighting installations. The low lamp voltage resulting from the elevated drive current results in a higher lumen efficacy thanks to a shorter and fatter filament, which limits heat losses compared to the situation in mains-voltage GLS lamps of comparable life rating. Moreover, the smaller low-voltage filament increases the source’s luminance, which is beneficial to the optical control of the emitted light. Finally, because those lamps are driven at constant current, they have a better lumen maintenance that standard GLS lamps due to an effective wattage rise over time as the filament evaporates and its ohmic resistance rises.

An interesting feature of series-circuit incandescent lamps made after the mid-1950s is their integrated voltage fuse which ensures continuity in the circuit after the lamp failure. This feature was most often implemented in the form of lead wires brought close together so as to facilitate the ignition of an arc in the event of filament rupture (the OCV of street-series circuits is several kV). This arc melts the lead wires which are quickly fused together, thereby quenching the arc and forming a robust short circuit. Such design greatly simplified the maintenance procedure since it eliminated the cut-out device that was usually inserted across the terminals of the lamp socket.

The GE 2500L shown here is the second smallest model of street-series lamps (after the 1000L) that were sold in North America. The lamp has an output of 2500 lumens, which was adequate for the illumination of secondary roads and of (small) town centers. This particular model is rated for a 3,000 h average service life, best suited for the group replacement of lamps during maintenance. Although the number of incandescent streetlight installations began to decline strongly during the 1980s, these lamps remained in production for several decades more. GE eventually discontinued them around 2010, which is quite remarkable given how inefficient the technology is compared to its HID counterparts.

- Not only do incandescent lamps operate more efficiently at low voltage and high current, interestingly their flux output is also more constant through life. Over time, the filament impedance increases as a result of evaporation, causing a slowly increasing wattage and output at source level (at constant current that is) which compensates for the optical absorption resulting from bulb blackening.

What is even more peculiar is the fact that those current-driven lamps are less prone to failure via filament hot spot formation than standard voltage-driven incandescent lamps. That's because when their thicker and stiffer filament breaks following hot spot melting, the resulting arc can weld the filament extremities back together. As a result it will take several of such transient phenomena before the filament fail so catastrophically that an arc will initiate between the lead wires and short the lamp permanently. On that subject, it's interesting to note that most of those lamps were operated in the vertical cap up position, and when a long-enough arc is struck between two filament sections after local melting, then a gliding arc effect (Jacob's ladder) occurs, i.e., convection and self induction force the arc to move upward and to transfer itself to the section where lead wires are close together, thus making the process of end-of-life shorting more reliable than at any other positions.

However, each re-welding of the filament lowers its impedance, causing a decrease in output flux. Lamps have been found with up to ten welds, resulting in a very low light output. Those lamps were referred to as “slumpers” and prompted manufacturers to push for group replacement, typically three times a year, in order to maintain a nominal output flux in installations. Nevertheless, despite the drawback of filament re-welding, this process also curbs early failures, which was a bonus from a safety point of view of a reduced light output is a much better outcome than no light at all in the first occurrence of filament rupture.


Keywords: Lamps

1972 GE 2500L (147 W / 6.6 A)


The lamp shown here has become quite a rarity nowadays as municipalities across North America have retired their obsolete incandescent streetlight luminaires with LED counterparts (or are in the process of doing so). The present 2500L is a special incandescent lamp which was designed specifically for an operation on 6.6 A series circuits that once were popular in the USA in street-lighting installations. The low lamp voltage resulting from the elevated drive current results in a higher lumen efficacy thanks to a shorter and fatter filament, which limits heat losses compared to the situation in mains-voltage GLS lamps of comparable life rating. Moreover, the smaller low-voltage filament increases the source’s luminance, which is beneficial to the optical control of the emitted light. Finally, because those lamps are driven at constant current, they have a better lumen maintenance that standard GLS lamps due to an effective wattage rise over time as the filament evaporates and its ohmic resistance rises.

An interesting feature of series-circuit incandescent lamps made after the mid-1950s is their integrated voltage fuse which ensures continuity in the circuit after the lamp failure. This feature was most often implemented in the form of lead wires brought close together so as to facilitate the ignition of an arc in the event of filament rupture (the OCV of street-series circuits is several kV). This arc melts the lead wires which are quickly fused together, thereby quenching the arc and forming a robust short circuit. Such design greatly simplified the maintenance procedure since it eliminated the cut-out device that was usually inserted across the terminals of the lamp socket.

The GE 2500L shown here is the second smallest model of street-series lamps (after the 1000L) that were sold in North America. The lamp has an output of 2500 lumens, which was adequate for the illumination of secondary roads and of (small) town centers. This particular model is rated for a 3,000 h average service life, best suited for the group replacement of lamps during maintenance. Although the number of incandescent streetlight installations began to decline strongly during the 1980s, these lamps remained in production for several decades more. GE eventually discontinued them around 2010, which is quite remarkable given how inefficient the technology is compared to its HID counterparts.

- Not only do incandescent lamps operate more efficiently at low voltage and high current, interestingly their flux output is also more constant through life. Over time, the filament impedance increases as a result of evaporation, causing a slowly increasing wattage and output at source level (at constant current that is) which compensates for the optical absorption resulting from bulb blackening.

What is even more peculiar is the fact that those current-driven lamps are less prone to failure via filament hot spot formation than standard voltage-driven incandescent lamps. That's because when their thicker and stiffer filament breaks following hot spot melting, the resulting arc can weld the filament extremities back together. As a result it will take several of such transient phenomena before the filament fail so catastrophically that an arc will initiate between the lead wires and short the lamp permanently. On that subject, it's interesting to note that most of those lamps were operated in the vertical cap up position, and when a long-enough arc is struck between two filament sections after local melting, then a gliding arc effect (Jacob's ladder) occurs, i.e., convection and self induction force the arc to move upward and to transfer itself to the section where lead wires are close together, thus making the process of end-of-life shorting more reliable than at any other positions.

However, each re-welding of the filament lowers its impedance, causing a decrease in output flux. Lamps have been found with up to ten welds, resulting in a very low light output. Those lamps were referred to as “slumpers” and prompted manufacturers to push for group replacement, typically three times a year, in order to maintain a nominal output flux in installations. Nevertheless, despite the drawback of filament re-welding, this process also curbs early failures, which was a bonus from a safety point of view of a reduced light output is a much better outcome than no light at all in the first occurrence of filament rupture.

Appleby20Incandescent20Bulkhead.jpg cfl_x.jpg GE_2500L_145W_-_USA_1972.jpg DSC00529.JPG Pointolite_diagram.jpg
Lamp/Fixture Information
Manufacturer:General Electric
Model Reference:2500 L
Lamp
Lamp Type:Incandescent
Filament/Radiator Type:Incandescent tungsten filament
File information
Filename:GE_2500L_145W_-_USA_1972.jpg
Album name:Max / Incandescent lamps
Keywords:Lamps
Filesize:375 KiB
Date added:Aug 17, 2024
Dimensions:1200 x 628 pixels
Displayed:6 times
DateTime Original:2010:11:21 10:06:34
Exposure Time:1/125 sec
FNumber:f/5
Flash:No Flash
Focal length:35 mm
ISO:800
Model:Canon EOS 450D
Software:Adobe Photoshop CS5 Windows
White Balance:1
URL:https://trad-lighting.net/gallery/displayimage.php?pid=258
Favorites:Add to Favorites

Comment 1 to 5 of 5
Page: 1

Ria   [Aug 17, 2024 at 12:00 PM]
I've always been intrigued by series incandescent lighting, it's something we never had here in the UK. We only have one example of a series lamp here, which I'll have to try and find the photo of. It's an Osram-GEC one as I recall, made in England, but exported to Australia. So it's been all the way around the world and come back home again..!
Sammi   [Aug 17, 2024 at 02:56 PM]
It would be interesting to have a Jacob's ladder as part of our collection. Wonder
Max   [Aug 18, 2024 at 09:03 AM]
You sure had series incandescent lighting if you ever had those old miniature incandescent Christmas light strings Wink
Ria   [Aug 18, 2024 at 10:39 AM]
Oh those things, yes I remember them..! We actually have an American C7 set that Robert sent us, but I don't think it's series fed, they're 120V lamps, I must check at some point.
I do vaguely remember incandescent street lighting being replaced with MV when I was about 5 years old or so, it was one of those defining moments that I think went towards my becoming a collector Incandescent lamp HD
Max   [Aug 18, 2024 at 02:39 PM]
I was born too late to witness the transition from incandescent to mercury in my neighborhood, although I do remember the incandescent streetlights in some of the most historical parts of Paris. Interestingly those skipped the mercury phase and went straight to white sodium and ceramic metal halide, the condition being that a warm-white light similar to that of incandescent lamps be emitted (the city of Paris has a really strict code).

Comment 1 to 5 of 5
Page: 1