About two years ago, a student and I designed and built a special UV calibration light source system that we now use at work with our spectrometers. The picture shows the open driver unit (right), with its internal electronics exposed, and the light source (left). That photo was shot at the end of the project, I was doing some final checks before putting the system in regular service, and we can see the blue fluorescence from a piece of paper on the left, exposed to the shortwave radiation emitted by the deuterium lamp. I switched it on only for the pictures.

The biggest uncertainty in the system design was the effect of the 1-m long shielded cable (so, high capacitance) on the lamp's ignition and on the driver's operation. The system is still being used in the lab today and I am happy to report that there has not been any issues so far :)


Keywords: Miscellaneous

Deuterium reference lamp system


About two years ago, a student and I designed and built a special UV calibration light source system that we now use at work with our spectrometers. The picture shows the open driver unit (right), with its internal electronics exposed, and the light source (left). That photo was shot at the end of the project, I was doing some final checks before putting the system in regular service, and we can see the blue fluorescence from a piece of paper on the left, exposed to the shortwave radiation emitted by the deuterium lamp. I switched it on only for the pictures.

The biggest uncertainty in the system design was the effect of the 1-m long shielded cable (so, high capacitance) on the lamp's ignition and on the driver's operation. The system is still being used in the lab today and I am happy to report that there has not been any issues so far :)

Sylvania_35_W_SHP.jpg _IMG8576.jpg _DSC2808m.jpg _DSC2776m.jpg _DSC2788m.jpg
File information
Filename:_DSC2808m.jpg
Album name:Max / Misc lamps and lighting
Keywords:Miscellaneous
Filesize:885 KiB
Date added:Sep 08, 2024
Dimensions:1200 x 798 pixels
Displayed:10 times
DateTime Original:2022:01:31 17:21:51
Exposure Time:1/10 sec
FNumber:f/5.3
File Source:Digital Still Camera
Flash:No Flash
Focal length:46 mm
ISO:450
Model:NIKON Z 6_2
Software:Adobe Photoshop CS5 Windows
White Balance:0
URL:https://trad-lighting.net/gallery/displayimage.php?pid=492
Favorites:Add to Favorites

Comment 1 to 8 of 8
Page: 1

Ria   [Sep 08, 2024 at 09:03 PM]
It's been a long time since I've done any electronics work, I'm more interested in mains power wiring these days. It doesn't help that I don't have any space for a decent work bench any more Confused
Tuopeek   [Sep 08, 2024 at 10:09 PM]
I see your ballast is mains powered. The one I have runs from a 24v supply. I don't know the original use of the Deuterium lamp I have but it was used with a filter marked 214nm. The lamp run inside an aluminium enclosure which also looks like a heat-sink for the lamp but the ballast has no forced cooling.
Sammi   [Sep 09, 2024 at 01:11 AM]
Another factor to consider is that long hair and soldering don't go well together... Laughing
Tuopeek   [Sep 09, 2024 at 10:55 AM]
Yeah, and you only catch a falling soldering iron once Laughing
Ria   [Sep 09, 2024 at 11:50 AM]
Ouch Mind Blown Angry Cursing Mr. Green
Max   [Sep 09, 2024 at 09:27 PM]
Tuopeek - It's a 24 V electronic control gear. The 24 V switched-mode power supply is under the deuterium ballast.

Ria - I don't have a proper work bench either. What you see here is my kitchen table...
Sammi   [Sep 09, 2024 at 10:29 PM]
Our kitchen is too small to have a table in it... Wonder
Well, we could have a table in there, but then there would be no room for us. Laughing
Max   [Sep 11, 2024 at 06:09 PM]
So, it's a simple question of priority then Wink