| FILE 30/30 | ![]() |
![]() |
![]() |
![]() |
| Lamp/Fixture Information | |
| Manufacturer: | The General Electric Company of England |
| Model Reference: | MA/H |
| Lamp | |
| Lamp Type: | Medium pressure mercury lamp |
| Filament/Radiator Type: | Aluminosilicate glass arc tube |
| Base: | E40 |
| Shape/Finish: | Tubular, clear |
| Burning Position: | Vertical cap up to horizontal |
| Electrical | |
| Current: | 4.2A |
| Physical/Production | |
| Factory Location: | Shaw, Oldham |
| Fabrication Date: | March 1960 (Date code RC) |
| File information | |
| Filename: | Osram-GEC_400W_MA-H.jpg |
| Album name: | Ria / Mercury Lamps |
| Keywords: | Lamps |
| Filesize: | 348 KiB |
| Date added: | 21 Jul 2024 |
| Dimensions: | 2245 x 1587 pixels |
| Displayed: | 863 times |
| URL: | https://trad-lighting.net/gallery/displayimage.php?pid=81 |
| Favourites: | Add to Favourites |
Comment 1 to 16 of 16 Page: 1 |
|
|||
|
Looking forward to seeing this rare beast lit again.!
|
|
|||
|
Indeed, someone said a 400W SON ballast run at a slightly lower mains voltage should work, so we'll maybe try that soon.
|
|
|||
|
As the correct ballast is unobtanium, that's the best we can do.
|
|
|||
|
Think I have the same lamp, although with more hours on it. The start resistor has a connection issue but the outer jackets incomplete vacuum means it starts fine. I hadn't realised the current differs and have run mine up on a standard 400w MB/U mercury ballast. It does look like you might be running that horizontal though
but I'm sure you know you need a magnetic deflector for that.
|
|
|||
|
We are running it horizontally, and it was designed for that without the deflector, hence the higher current.
|
|
|||
|
Wow, thanks for the information Sammi, I need to find out more on this and check if mine is indeed the same.
|
|
|||
|
The MA/H lamps are like hen's teeth, our other ones, which look the same, are the usual MA/V lamps, have a shufti at the etch.
|
|
|||
|
Ah, that sounds rare right enough think it might be the MA/V I have.
|
|
|||
|
Yeah, the genuine MA/H version is rather a rare beast, apparently it has a hard glass arc tube so is more able to withstand horizontal burning, but from what I can gather, the genuine ballast for it has a different tapping, not sure
|
|
|||
|
I see what you mean, it looks more or less physically identical to the MA/V.
Also see a mention to 'special choke tapping' for the MA/H but not 100% clear if that's on the 400w MA/V choke. Glad you have this in your collection I would have missed this otherwise
|
|
|||
|
So are we.!
|
|
|||
|
@Tupoeek - I think there was a special ballast for it, but not sure. I'm guessing so, given the higher current requirement.
|
|
|||
|
Somehow I missed this post. Really interesting lamp! Although I knew about the /H variant of this MA type, I had not realized that electrical characteristics where so much different! It looks like the mercury pressure is reduced in order to lower the heat transfer from the arc to the glass wall, a trick used also by GE in its 250 W A-H2.
|
|
|||
|
I haven't tried running it again since I took this picture, I'll try using the Variac to alter the lamp current and see what happens.
|
|
|||
|
Those lamps operate in the unsaturated vapor regime, changing the current (over a reasonable range) won't change its discharge properties much. Have you measured its voltage? It should be lower than that of the /V variant.
|
|
|||
|
Not yet, but we'll get the lamp out soon and try a few things.
|
Comment 1 to 16 of 16 Page: 1 |